AGS ANALÍTICA
  • Home
  • Productos
    • Cromatografía Líquida (HPLC)

      • Liquid Cromatographs (HPLC)
      • Preparative Scale HPLC
      • Biochromatography HPLC
      • SMB (Simulated Moving Bed)
      • HPLC Autosamplers
      • HPLC Columns
      • Degassers
      • Post-column Derivatization Instruments
      • Solvent Recycling Units
    • Cromatografía Gaseosa (GC)

      • Special applications GC
      • Gas Generators
      • Liquid GC Autosamplers
      • GC All in one Autosamplers
      • Headspace Samplers
      • Purge and Trap Concentrators
      • Purge and Trap Autosamplers
      • GC Inlets
      • GC Detectors
      • GC/MS Interfaces
      • Multistream Gas Sampler
      • Direct Mass Spectrometers (Sift-MS)
    • Espectrómetros de Masas

      • MALDI-TOF and TOF/TOF
      • timsTOF (Trapped Ion Mobility Spectrometry - Time of Flight)
      • MRMS: Magnetic Resonance Mass Spectrometry
      • QTOF. Ultra High Resolution
      • EVOQ GC-Triple Quad
      • EVOQ LC-Triple Quad
      • Ion Trap Mass Spectrometry
    • Equipos varios

      • Producción de nanopartículas lipídicas (LNP)
      • Spectroscopy Autosamplers
      • Sample Prep Workstations
      • Density meters
      • Modified Atmosphere Testers
      • Melting Point Meters
      • Osmometers
    • Equipos ópticos

      • UV-Visible Spectrophotometers
      • Polarimeters
      • Refractometers
      • Laboratory Microscopes
      • Stereo Microscopes
      • Flame Photometers
    • Software

      • Chromatography Data System (CDS)
      • Mass Spectral Libraries
  • Representadas
    • Biotech
    • Data Apex
    • Joint Analytical Systems
    • F-DGSi
    • EST Analytical
    • A.KRÜSS Optronic GmbH
    • Wiley
    • Knauer
    • HTA
    • Syft Technologies
    • G.A.S.
    • Dionamix Scientific
    • Bruker
    • Shine
  • Soporte técnico
  • Nosotros
  • Contacto
  • [Notas Técnicas]
  • AGS ANALITICA
  • +54 11 4524 7247
  • Inglés
    • Español

MALDI-TOF and TOF/TOF

MALDI-TOF and TOF/TOF

ultrafleXtreme

Bruker

The industry standard MALDI- TOF/TOF mass spectrometer with 5 GS/s 10 bit digitizer for enhanced dynamic range.

Further enhanced ultrafleXtreme, proven technology taken to the next level.

Attain the highest level of mass spectrometry performance with the enhanced ultrafleXtreme, an Instrument exceeding all your expectations.

Combining true 2 kHz speed in TOF mode and 1 kHz in TOF/TOF mode with a 10 bit digitizer for enhanced dynamic range and extreme flexibility for a broad variety of complementary research, biopharmaceutical and applied...

Solicitar más información
Información adicional

Información adicional

The innovative smartbeam-II™ laser enables ultra-high data acquisition speed in both MS and MS/MS at full systems performance. The well-established proprietary smartbeam laser provides unprecedented analytical and matrix flexibility in workflows from protein tissue imaging, intact proteins analysis, Glycoproteomics, biologics or oligo QC, to LC-MALDI proteomics - all fully enabled at 1-2000 Hz repetition rates.

Bruker's patented smartbeam technology is already widely accepted as the most viable MALDI imaging laser technology. The new ultrafleXtreme now enables low pixel sizes for high spatial resolution imaging. Importantly, outstanding spectral quality and signal intensity are maintained at even the smallest laser beam diameters.

Broadband mass resolving power up to 40,000 enables precision proteomics via Bruker’s unique PAN™ technology for highest mass resolution across a very broad mass range, not just at a selected optimum.

The novel FlashDetector™ combined with a minimum of 5 GS/s 10 bit digitizer and latest advances in electronics provide unmatched mass resolving power up to 40,000 and 1 ppm mass accuracy for highest confidence.

The novel and unique laser-irradiation self-cleaning Ion Source ensures robust, long-term highest-performance operation. Very long MALDI laser lifetime in combination with automated source cleaning in just minutes leads to high uptime and low maintenance costs.

Latest TOF/TOF technology: The high efficiency and sensitivity of the LID-LIFT process delivers MS/MS spectra with nominal mass resolution for peptides. Typically, full MS/MS data sets can be acquired with up to 1000 Hz laser repetition rate from low fmol levels within seconds. The Bruker bioinformatics software is perfectly adapted to analyze and visualize the match between the raw spectra and annotated peptide and protein structures.

As a result, proteins can be identified with high confidence with unmatched ease.

Smart combination of technological features is key for ultrafleXtreme top-performance.

Descargar folleto
Links
  • Más productos Bruker
  • Más sobre ultrafleXtreme

Reciba nuestras Notas técnicas

Suscríbase y reciba consejos técnicos y novedades de nuestros productos,
apenas los publiquemos online.
(Puede leer aquí nuestras notas)

¡Genial! Vas a recibir nuestras notas
técnicas apenas se publiquen
Te enviaremos notas, consejos sobre cromatografía, lanzamientos y promociones
*Por favor confirme que al suscribirse, acepta recibir información de AGS ANALITICA S.A.
*AGS ANALITICA S.A. cumple con la ley Nacional de protección de datos personales 25.326
¡Entendido! Si en algún momento
cambias de opinión, aquí estaremos.
  • Biotech
  • Data Apex
  • Joint Analytical Systems
  • F-DGSi
  • EST Analytical
  • A.KRÜSS Optronic GmbH
  • Wiley
  • Knauer
  • HTA
  • Syft Technologies
  • G.A.S.
  • Dionamix Scientific
  • Bruker
  • Shine
AGS ANALÍTICA
  • Linkedin
  • Youtube

Arenales 605 - Piso 15 (B1638BRG)
Vicente López, Pcia. de Buenos Aires - Argentina

Tel: 011 4524 7247
Fax: 011 4524 7247 (opción 2)
Email: info@agsanalitica.com

Horario de atención telefónica:
Lunes a Viernes, de 9:00 a 17:00

*AGILENT®, Chemstation® y Varian® son propiedad de Agilent Technologies, Inc. AGS ANALÍTICA S.A. no es representante ni tiene ninguna vinculación con Agilent Technologies, Inc.
Hewlett Packard® es propiedad de Hewlett-Packard Company. AGS ANALITICA S.A. no está vinculada a Hewlett-Packard Company.

® 2025 AGS ANALITICA S.A.

AGS ANALITICA S.A cumple con la ley nacional de ​​protección de datos​​ personales 25.326. Más información
Diseño Web
Data Fiscal